Author :
Rameshpetchi Rajendran, Devikasubramaniyan*, Ramya Sri Sura, E.Veeranna, G.Chandraprabha, G.Kiranmai, G.Tharunkumar
Volume :
5
Issue :
04
Abstract :
A rapid and precise Reverse Phase High Performance Liquid Chromatographic method has been developed for the
validated of Prulifloxacin in its pure form as well as in tablet dosage form. Chromatography was carried out on
Symmetry C18 (4.6×150mm, 5µ) column using a mixture of Methanol and water (85:15 v/v) as the mobile phase at
a flow rate of 1.0ml/min, the detection was carried out at 242nm. The retention time of the Prulifloxacin was 3.0
±0.02min. The method produce linear responses in the concentration range of 15-75µg/ml of Prulifloxacin. The
method precision for the determination of assay was below 2.0%RSD. The method is useful in the quality control of
bulk and pharmaceutical formulations.
Keywords: Prulifloxacin, RP-HPLC, validation.
Keyword :
Prulifloxacin, RP-HPLC, validation.