Development and validation of stability-indicating RP-HPLC method for the estimation of azoxystrobin in its formulations


Article PDF :

Veiw Full Text PDF

Article type :

Original Article

Author :

G. Rahul, N. Venkatasubba Naidu, V.Venkata lakshmi, B. Ramachandra

Volume :

9

Issue :

1

Abstract :

The current work established and validated a simple, selective, precise, and accurate HighPerformance Liquid Chromatographic technique (HPLC) for the analysis of Azoxystrobin in its formulations. The mobile phase is made up of a combination of mobile phases comprising Acetonitrile and water in proportion, 80:20 (v/v). At a run duration of 15 minutes, this was found to yield a sharp peak of Azoxystrobin. Azoxystrobin was analysed using HPLC at a wavelength of 255 nm at a flow rate of 1.0 mL/min. The calibration curve's linear regression analysis results revealed a satisfactory linear connection with a regression coefficient of 0.999 in the concentration range of 50% to 150 %. The linear regression equation was y = 2025x 123.2.The proposed approach was used to analyse Azoxystrobin with a high degree of precision and accuracy.The method was validated for precision, accuracy, specificity, ruggedness and robustness. This method is useful for the quantification of Azoxystrobin because of its precision, accuracy, short retention duration, sensitivity, and mobile phase composition.

Keyword :

RP­HPLC, Azoxystrobin, Forced Degradation, ICH guidelines, Method validation