Abstract :
A simple and selective LC method is described for the determination of ASENAPINE dosage forms.
Chromatographic separation was achieved on a C18 column using mobile phase consisting of a mixture of
Triethylamine Buffer: Acetonitrile (50:50) with detection of 220nm. Linearity was observed in the range 15-45 µg
/ml for ASENAPINE (r2 =0.997) for the amount of drug estimated by the proposed methods was in good agreement
with the label claim.
The proposed methods were validated. The accuracy of the methods was assessed by recovery studies at three
different levels. Recovery experiments indicated the absence of interference from commonly encountered
pharmaceutical additives. The method was found to be precise as indicated by the repeatability analysis, showing
%RSD less than 2. All statistical data proves validity of the methods and can be used for routine analysis of
pharmaceutical dosage form.
Key Words: Reverse Phase- High Performance Liquid Chromatography (RP-HPLC), Asenapine, r2 correlation
coefficient.
Keyword :
Reverse Phase- High Performance Liquid Chromatography (RP-HPLC), Asenapine, r2 correlation coefficient.